Operating and installation manual for VR 61 mixer module14
– Display screen A3
Installation assistant
System configuration
Relay output ZP/LP:
> Select
ZP
A 3
Fig. 7.2 Installation assistant display screen A2
h
Note!
If the heating system is structured according to
hydraulic drawing2 or 4, the relay output ZP/LP
must be set to "LP".
– Display screen A5
Installation assistant
Module test
Module selection
> Select
VR 61
A 5
Activation heat generator
OFF
Sensors
Actors HK1-P
VF2
Fig. 7.3 Installation assistant display screen A5
On display screen A5 of the installation assistant you
can select the components for which a function test
should be carried out (the components are actuated
briefly).
It is a pre-requisite that "VR 61" is selected as the
module selection.
Sensors Actuators
VF2 Feed sensor 2 LP/ZP
Charging pump/
circulation pump
HK1-P Pump heating circuit 1
HK2 Mixer valve
HK2-P Pump, heating circuit 2
Table 7.1 Components for function test in display screen A5
a
Attention!
Improper installation/assembly can lead to
damage to the heating system.
A function test of the components should be
carried out using the installation assistant
within the framework of the start-up.
If you wish to leave the installation assistant:
Turn the left hand adjuster of the controller
VRC 430 VRC 430f in a clockwise direction to
reach the display screen A6.
Confirm the termination of the installation with
"Yes".
h
Note!
If you have confirmed the end of the installation
with "Yes" you can only access the
installation assistant via the code-protected
expert technician level (see
installation instructions VRC 430 or
VRC 430f).
7.2 VRC 430 / VRC 430f Operating
level for the expert technician
The operating level for the expert technician serves to
display and for the setting/modification of
specific operating data. This will match the control
system to the heating system in an optimum manner.
This is advisable if the heating installation has other
components in addition to the heating circuit 1 (HC 1)
(e.g. heating circuit 2, hot water storage tank, ventilation
system, solar system).
The operating level for the expert technician includes
the display screens C1 to C26 and the display screens
A1 to A6 of the previously described installation
assistant.
Depending upon the configuration of the heating system,
the display screens not required are hidden.
The display screens C1 to C26 in the controller
VRT430 or VRC 430f in the same sequence as shown in
the following Table 7.2.
This table shows which parameters can be adjusted and
changed.
The following differences in the displat screens are
produced by the installation of the mixer module
VR 61 in the heating system with respect to the standard
configuration as described in the manual for the
VRC 430 or VRC 430f:
C2, C4, C10, C11, C15, C22, C23 and C26
7 Start-up