4 On-roof fitting and installation
20 Installation manual auroTHERM exclusive 0020077994_02
4.1.8.1
Adjacent array configuration
1. Define the clearances of the roof brackets.
Quantity
A B C D
VTK
570/2
VTK
1140/2
‑ 1
1663 * /
1638 **
100 -
200
VTK
1140
997 -
1197
‑‑‑‑‑
VTK
570
507 -
607
1397
‑ 2
2794
‑ 3
4191
‑ 4
5588
‑ 5
6985
‑ 6
8382
‑ 7
9779
1 1
2104
1 2
3501
1 3
4898
1 4
6295
1 5
7692
1 6
8382
2. Ensure that there is sufficient play for the anchors.
Specifications/technical data
Pre-installation dimension (*) = Finished installation
dimension (**) + 20-
25 mm
4.1.8.2
Array configuration on top of each
other
Note
In the case of roof batten clearances greater
than 460 mm, the 2-row and 3-row installations
are not possible. In this case, you can install the
2 or 3 rows individually (without using the same
central roof anchor).